57.4mm Mounting Hole Single Phase Circuit Breakers, Used For Single Phase Oil Immersed Distribution Transformers.CSP Circuit breaker Is Installed On The Secondary Winding Of the Transformer, is Used For Over Load Protection And Short circuit Protection.
| Model | 2P105T110 |
| Rated Current | 105A |
| For Transformer | 25KVA/50KVA |
| Rated Voltage | 240V/480V |
| Trip Temp. | 110℃, 120℃, 130℃ |
| Phase | 1F |
| Mounting Hole Diameter | 57.4mm |
It is single phase circuit breakers, used for single phase transformers. Circuit breaker is installed on the secondary winding of the transformer, is used for over load protection and short circuit protection.
| Model | Current (A) | Rating (KVA) | Voltage (V) | Signal light | Emergency switch (overload) | Magnetic protection | Resistance (Ω) at 25°C 2 poles | Loss (W) at 85°C 2 poles |
|---|---|---|---|---|---|---|---|---|
| 2P21TXXX | 21 | 5 | 240 | Yes | Yes | No | 3800 | 2.1 |
| 10 | 480 | |||||||
| 2P42TXXX | 42 | 10 | 240 | Yes | Yes | No | 3200 | 2.1 |
| 2P63TXXX | 63 | 15 | 240 | Yes | Yes | No | 2100 | 10 |
| 2P105TXXX | 105 | 25 | 240 | Yes | Yes | No | 900 | 12 |
| 50 | 480 | |||||||
| 2P157TXXX | 157 | 37.5 | 240 | Yes | Yes | Yes | 800 | 24 |
| 75 | 280 | |||||||
| 2P210TXXX | 210 | 50 | 240 | Yes | Yes | Yes | 750 | 41 |
| 100 | 280 | |||||||
| 2P313TXXX | 313 | 75 | 240 | Yes | Yes | Yes | 500 | 60 |
| 150 | 480 | |||||||
| 2P420TXXX | 420 | 100 | 240 | Yes | Yes | Yes | 450 | 98 |
| 200 | 480 |
| Max Voltage | Power Frequency Test (one minute) 50/60HZ | Lightening Impulse Test | Insulation Resistance (5000V) | Normal Interrupting Capacity |
|---|---|---|---|---|
| 600V | ≥10KV | 30KV | ≥5000MΩ | 11KA~20KA |
| Model | Current (A) | Interrupting Capacity(KA) |
|---|---|---|
| 2P42TXXX | 42 | 11 |
| 2P63TXXX | 63 | 11 |
| 2P105TXXX | 105 | 11 |
| 2P157TXXX | 157 | 11 |
| 2P210TXXX | 210 | 11 |
| 2P313TXXX | 313 | 20 |
| 2P420TXXX | 420 | 20 |
(Trip temperature = Bi-metal trip temperature)
| No. | Bimetal ID | Current (I: A) | Bi-metal Ampere Response Factor (J: °C/A²) | Bi-metal temperature rise to oil (ΔT: °C) | Oil temperature (To: °C) | Bi-metal temperature (T: °C) |
|---|---|---|---|---|---|---|
| 01 | 21 | 21 | 0.0125000 | 5.5 | To | 5.5+To |
| 02 | 42 | 42 | 0.0040000 | 7.1 | To | 7.1+To |
| 03 | 63 | 63 | 0.0019904 | 7.9 | To | 7.9+To |
| 04 | 105 | 105 | 0.0008114 | 9.5 | To | 9.5+To |
| 05 | 157 | 157 | 0.0002000 | 4.9 | To | 4.9+To |
| 06 | 210 | 210 | 0.0001120 | 4.9 | To | 4.9+To |
| 07 | 313 | 313 | 0.0000610 | 6.0 | To | 6.0+To |
| 08 | 420 | 420 | 0.0000720 | 12.5 | To | 12.5+To |
| 09 | 433 | 433 | 0.0000720 | 13.5 | To | 13.5+To |
T:Bi-metal temperature(℃ )
ΔT:Bi-metal temperature rise to oil(℃ )
To:oil temperature(℃)
I:Current flow through the Bi-metal trip in(A)
J:Bi-metal Ampere Response Factor in (J:℃ /A²)
ΔT=I2*J
T= ΔT+To
Note: When Bi-metal temperature reaches the trip temperature setting of the breaker,the breaker trip.
The following drawings show only partial product dimensions.
For the complete set of engineering drawings or full specifications, please contact us at [📪nancywang@ketranele.com].

Thank you for using our CSp type circuit breakers, when you receive circuit breakers, please be informed with the following tips:
❶ If you need put the circuit breakers into dry oven for drying process, please make sure remove the lamp cover; lampbulb and lamp sealing ring before put into dry oven.
❷ After long-time drying process, it maybe make a few circuit breakers dificult to operate on opening and closing, youcan just put some transformer oil on the circuit breakers,it will work smoothly again.


Q1: How Does a CSP Circuit Breaker Work?
A1: Over current Protection Function: When the current exceeds the rated capacity, the thermal-magnetic trip mechanism detects overloads or short circuits.It automatically disconnects the circuit, preventing conductor overheating or equipment failure.
Q2: How To Install Csp Circuit Breaker On The Tank Wall Of Transformer?
A2: Oil-immersed circuit breakers provide better cooling, insulation, and resistance to outdoor environments, making them ideal for remote or harsh locations. Vacuum types are preferred for indoor or high-frequency switching applications.
Q3: Do You Provide Oem/Odm Services?
A3: Routine oil sampling and mechanical inspection are recommended every 3–5 years; under normal operation, maintenance requirements are minimal.
Q4: What Is The Typical Lead Time For Orders?
A4: Standard models are available in stock; customized orders usually require 3–4 weeks.